Model | D1-33- PA | D2-33- PA | D3-33- PA | D4-33- PA | D5-33- PA | D6-33- PA | D7-33- PA | ||||
Rated Current | 25A 40A | 75A 90A | 110A | 120A 150A | 200A | 250A | 300A 400A | 500A 600A | |||
Dimension (mm) |
Image | Image 1 | Image 2 | Image 3 | |||||||
W | 115 | 115 | 115 | 145 | 145 | 145 | 300 | 390 | |||
L | 165 | 230 | 230 | 245 | 315 | 315 | 360 | 430 | |||
H | 170 | 170 | 180 | 210 | 210 | 225 | 225 | 260 | |||
Install dimensi m) |
Image | Image 4 | |||||||||
W | 105 | 105 | 135 | 135 | 135 | 200 | 250 | ||||
L | 95 | 160 | 150 | 205 | 205 | 345 | 410 | ||||
M6 | M8 | M10 |
Rated Voltage | Three-phase 380VAC±15% (three phase three/four wire)/50Hz/60Hz |
Auxiliary power | 220VAC±15% 50Hz/60Hz |
Output Mode | Phase output / zero-crossing /Zero crossing sampling output (three ways to switch) |
Control Signal | 4-20mA,1-5VDC,2-10VDC ,0-20mA,0-5VDC,0-10VDC *Manual 2-10K potentiometer adjustment * Enter the control layer can switch to digital input mode for adjustment *Signal can be selected for switching, factory default control signal: 4-20mA |
Main Function |
Display function:LED panel shows SCR working status ,Body temperature and fault codes |
Overcurrent protection:Using fast fuse overcurrent protection | |
Overtemperature shutdown: body temperature exceeds 85ºC, SCR stop working | |
Start stop function: Short circuit of terminal RUN/Stop to start, disconnect and stop | |
Alarm output: After a fault alarm, there are two sets of normally closed/normally open relay outputs | |
Quick switching: One click quick switching between manual/automatic output | |
Use Environment | Temperature: -10-45ºC,humidity: less than 90%RH |
Product model | Three-phase three-wire star connection | Built-in fast melt model | Built-in module model | Built-in fan model | trigger board | |||
maximum power usage | Maximum use current | |||||||
Three-phase total power | power per phase | Three-phase total current | Current per phase | |||||
D1-33-25PA | ≤8.4KW | ≤2.8KW | ≤37.5A | ≤12.5A | RG11-25A | SCR-DX-25A/H2 | EC90 fan /AC220V | D2-SCR (three-phase ) |
D1-33-40PA | ≤13KW | ≤4.3KW | ≤60A | ≤20A | RG11-50A | SCR-DX-40A/H2 | EC90 fan /AC220V | D2-SCR (three-phase ) |
D2-33-75PA | ≤25KW | ≤8.3KW | ≤112.5A | ≤37.5A | RGS4-75A | SCR-DX-75A/H2 | EC90 fan /AC220V | D2-SCR (three-phase ) |
D2-33-90PA | ≤30KW | ≤10KW | ≤135A | ≤45A | RGS4-100A | SCR-DX-90A/H2 | EC90 fan /AC220V | D2-SCR (three-phase ) |
D2-33-110PA | ≤36.6KW | ≤12.2KW | ≤165A | ≤55A | RGS4-110A | SCR-DX-120A/H2 | EC90 fan /AC220V | D2-SCR (three-phase ) |
D3-33-120PA | ≤40KW | ≤ 13 . 3KW | ≤180A | ≤60A | RGS12-120A | SCR-DX-125A/H3 | EC120 fan /AC220V | D4-SCR (three-phase ) |
D3-33-150PA | ≤50KW | ≤ 1 6 . 6KW | ≤225A | ≤75A | RGS12-160A | SCR-DX-150A/H3 | EC120 fan /AC220V | D4-SCR (three-phase ) |
D4-33-200PA | ≤66KW | ≤22KW | ≤300A | ≤100A | RS95F-200A | SCR-DX-200A/H3 | EC120 fan /AC220V | D4-SCR (three-phase ) |
D5-33-250PA | ≤83KW | ≤ 2 7 . 6KW | ≤375A | ≤125A | RS95F-250A | SCR-DX-250A/H3 | EC120 fan /AC220V | D4-SCR (three-phase ) |
D6-33-300PA | ≤100KW | ≤ 3 3 . 3KW | ≤450A | ≤150A | RS95H-300A | MTC-300A-YJ | EC90 fan /AC220V | D4-SCR (three-phase ) |
D6-33-400PA | ≤133KW | ≤ 4 4 . 3KW | ≤600A | ≤200A | RS95H-400A | MTC-400A-YJ | EC90 fan /AC220V | D4-SCR (three-phase ) |
D7-33-500PA | ≤166KW | ≤ 5 5 . 3KW | ≤750A | ≤250A | RS95H-450A | MTC-500A-YJ | EC120 fan /AC220V | D4-SCR (three-phase ) |
D7-33-600PA | ≤200KW | ≤ 6 6 . 6KW | ≤900A | ≤300A | RS95H-500A | MTC-600A-YJ | EC120 fan /AC220V | D4-SCR (three-phase ) |
1. The main circuit adopts three-phase three-wire input without requirement for phase sequence.
2. Applicable load: Constant impedance, IR far-infrared Ray, UV lamp, etc.
3. When loading Y connection, the center point cannot be connected with zero line, otherwise, the SCR will lose control. if three-phase load is unbalanced, the center point must be connected with the zero line, our product of three-phase four-wire system can be chosen.
4. SCR is wall-mounted, and vertical installation for optimum heat dissipation.
5. SCR is a product with big current, Please be sure to lock the terminal (R.S.T) and (U.V.W) tightly or SCR will be burned by terminal heating.
6.There is a fast fuse built in SCR for over current and short-circuit protection. When the fuse is blown off(the yellow light is on), first check whether the load has short circuit, partial discharge ignition and other faults. After troubleshooting, open the panel to replace, please be sure to use the same size fuse to replace. Be careful not to increase the amp number of the fuse arbitrarily.
7.When the temperature of radiator over 85ºC,SCR will stop working automatically, please check whether the actual load current is out of the range of SCR. The environment of SCR should be improved to make it well ventilated. Power on and operating after troubleshooting.
8.When the load is not used, disconnect the control signal to make the SCR output zero, and then cut off the power supply of the main circuit.
9.Operating environment: Please use in well-ventilated environment free from direct sunlight , thermal radiation, corrosivity or flammability.