Customization: | Available |
---|---|
Theory: | Solid State Relay |
Usage: | Car Relay, Household Appliances Relay, Communication Relay |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Input and output electro-optic isolation or transformer isolation;
2.Input constant current control and LED display,control signal and TTL & CMOS logic is compatible;
3.Bidirectional controlled sillion or unidirectional controllable counter-parallel output,zero electric current opening zero electric current shutdown;
3.Power solid state uses the SCR chip counter-parallel output and working is stable;
4.Buit-in resistance-capacitance absorbing circuit,dead zone voltage and small harmonic interference;
5.Higher than of 2.5KV safe isolation voltage between the input output and ledger wall's;
6.Small volume,small input power, non-contact, sparkless, noiseless, non-machinery wear, anti-vibration and the long life
Technology Data:
ST5-5DD | |
Load Current | 5Ax5 |
Load Voltage | 24VDC |
Control Voltage | 24VDC |
Control Current | ≤2mA |
On Voltage | ≤1.5V |
Off Leakage Current | ≤4mA |
On-off time | ≤10mS |
Dielectric Strength | 2000VAC |
Insulation Resistance | 500MΩ/500VDC |
Ambient Temperature | -20~+70°C |
Mounting Mthods | Bolt Fixing |
Working Station Indicator | LED |
Weight | 60g |
Din rail mounting SSR dc dc ST5-5DD
DIMENSIONS SHOWING:
Din rail mounting SSR dc dc ST5-5DD
HARDWARE SCHEMATIC:
Din rail mounting SSR dc dc ST5-5DD
OPERATION NOTICE:
1.Resistive load could not exceed 60% of the rated current.
2.Inductive or capacitive load could not exceed 40% of the rated current.
3.Electric machine load could not exceed 20% of the rated current.
4.Proper radiator adapted to the working requirement of solid state relay should be equipped, the allowance should be widened when the load radiating condition is not so good. Short-circuit load is not allowable.
5.Over Current Protection: over current and short circuit are the main reasons for permanent damage of output controllable silicon in the SSR, and using fast fuse and air switch is one of methods for over current protection, fuse is also available for small capacity.
6.Over Voltage Protection: It can adopt parallel voltage-dependent resistance(MOV), the MOV area decides the absorption power, while its thickness decides the protective voltage value, generally, 471/10D voltage-dependent resistance for 220V series SSR, 681/10D voltage-dependent resistance for 380V series SSR, 821/10D voltage-dependent resistance for 480V series SSR.
6.37
1. Q: Can you provide OEM service?
A: Yes, we can.
2. Q: What's the MOQ?
A: For testing purpose, 1pc is ok.
3. Q: Can you provide trade assurance service?
A: Yes, we are member of the trade assurance scheme.
4. Q: What's the lead time?
A: General lead time is 15 days after payment.
5. Q: What's your waranty?
A: We provide 12 months warranty against manufacturing defective.